The Borri UPSaver and UPSaver 3vo UPS (uninterruptible power supply) is a very high efficiency, multi function and fully adaptable three phase modular UPS system supplying online double conversion power. The power modules provide flexibility of the system and can be configured as either a standalone unit or in a modular framework.

The Borri UPSaver is available from 400kVA and can be scaled up to 12.8MW and the UPSaver 3vo is available from 670kVA and is scalable up to 21MW. Both modular UPS systems achieve a maximum efficiency of 99.5%

  • Modules are available in 200kW increments for the UPSaver and 333kW modules UPSaver 3vo
  • Configuration options include N+R redundancy, distributed and centralized static bypass
  • Low environmental footprint transformer free design with a unity power factor
  • 4 level modularity
  • Hot swappable batteries and modules for easy maintenance
  • High efficiency even at low loads
  • 4 operation modes – double conversion (VFI), active filtering (VI), ECO mode (VFD) and ultra high efficiency mode (VFD)
  • Detection of circuitry and input disconnection for maximum operator safety
  • Unity input power factor

UPSaver technical specification

WARRANTY 1 Year Parts (upgradable to 5 Years)
RATING KVA 400 – 1600
N NOMINAL POWER 400kW – 1600kW
N+1 NOMINAL POWER 200kW – 1400kW
DIMENSIONS (WxDxH) 2350x 970x 2100 (400kVA) 2950x 970x 2100 (600kVA) 3900x 970x 2100 (800kVA) 4500x 970x 2100 (1000kVA) 5100x 970x 2100 (1200 kVA) 6800x 970x 2100 (1400kVA) 7400x 970x 2100 (1600kVA)
WEIGHT 1660KG (400kVA) 2260KG (600kVA) 2920KG (800kVA) 3590KG (1000kVA) 4190KG  (1200 kVA) 4960KG (1400kVA)5560KG (1600kVA)
INPUT PHASE Three Phase
INPUT VOLTAGE TOLERANCE RANGE ‘-20%, +15% (rectifier); ±10% (bypass)
INPUT FREQUENCY 50/60 Hz, 45 to 65 Hz
OUTPUT PHASE Three Phase
OUTPUT POWER FACTOR Any power factor (leading or lagging) up to 1, without power derating
OUTPUT WAVEFORM Sinusoidal
OUTPUT VOLTAGE 380/400/415 Vac 3-phase with neutral
OUTPUT FREQUENCY 50/60 Hz
OUTPUT EFFICIENCY Up to 99.5%
BATTERY CONFIGURATION External 360 to 372 cells, VRLA (other options)
OPERATING TEMPERATURE TOLERANCE 0 – 40°C
RELATIVE HUMIDITY <95% (non-condensing)
COMMUNICATION Included: serial RS232 and USB; input terminal block (remote emergency power off, battery circuit breaker aux. cont., external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont., external output circuit breaker aux. cont., remote transfer to bypass mode); SPDT contact relay board; ModBus-RTU (RS485);Optional: ModBus-TCP/IP (Ethernet); ModBus-RTU to PROFIBUS DP adapter
OPTIONAL COMMS extended VFC
PARALLEL Up to 8 UPS, for a total of 12.8 MW
FUNCTIONS Optional: Isolation transformer; custom battery cabinets; wall-mounted battery fuse switch box; battery thermal probe; parallel kit; load-sync for single UPS and load-sync box (2 UPS systems); other options on request

 

UPSaver 3vo technical specification

WARRANTY 1 Year Parts (upgradable to 5 Years)
RATING KVA 670 – 2670
N NOMINAL POWER 670kW – 2670kW
NO OF MODULES 2-8
DIMENSIONS (WxDxH) 2450x 970x 2100 (670kVA) 3050x 970x 2100 (1000kVA) 4100x 970x 2100 (1340kVA)4700x 970x 2100 (1670 kVA) 5700x 970x 2100 (2000 kVA)
WEIGHT 1800KG (670kVA) 2540KG (1000kVA) 3170KG (1340kVA) 3900KG (1670kVA) 4700KG  (2000kVA)
BATTERY CONFIGURATION External 360 to 372 cells, VRLA (other options)
INPUT PHASE Three Phase
INPUT VOLTAGE TOLERANCE RANGE ‘-20%, +15% (rectifier); ±10% (bypass)
INPUT FREQUENCY 50/60 Hz, 45 to 65 Hz
PARALLEL Up to 8 UPS, for a total of 12.8 MW
OUTPUT PHASE Three Phase
OUTPUT POWER FACTOR Any power factor (leading or lagging) up to 1, without power derating
OUTPUT WAVEFORM Sinusoidal
OUTPUT VOLTAGE 380/400/415 Vac 3-phase with neutral
OUTPUT FREQUENCY 50/60 Hz
OUTPUT EFFICIENCY Up to 99.5%
OPERATING TEMPERATURE TOLERANCE 0 – 40°C
RELATIVE HUMIDITY <95% (non-condensing)
COMMUNICATION Included: serial RS232 and USB; input terminal block (remote emergency power off, battery circuit breaker aux. cont., external maintenance bypass circuit breaker aux. cont., diesel mode aux. cont., external output circuit breaker aux. cont., remote transfer to bypass mode); SPDT contact relay board; ModBus-RTU (RS485);Optional: ModBus-TCP/IP (Ethernet); ModBus-RTU to PROFIBUS DP adapter
OPTIONAL COMMS extended VFC
FUNCTIONS Optional: Isolation transformer; custom battery cabinets; wall-mounted battery fuse switch box; battery thermal probe; parallel kit; load-sync for single UPS and load-sync box (2 UPS systems); other options on request