Code: R148310020000

  •  Alarm relay: Yes
  •  Measurement Range (V): 230
  •  Power supply (Vac): 230 Vac
  •  Nr steps: 6
  •  Input current: … / 5A
  •  Switching unit: Contactor

The Computer C Wi-Fi series of regulators is designed for simple and effective regulation. Its high-contrast display can show up to 27 electrical parameters.
Its features are key to having a robust and reliable system, as well as to obtaining the necessary warnings and alarms for its proper monitoring and control:

  • Up to 12 fully configurable alarms.
  • Electrical parameters viewable online via Wi-Fi connectivity.
  • Plug & Play.
  • For easier preventive maintenance

 

APPLICATIONS

The Computer C Wi-Fi is the ideal regulator to compensate balanced installations, where ease of programming, robustness, precision, and maximum compensation control are required.
Its simple and intuitive programming system facilitates user installation and maintenance.

AC POWER SUPPLY
Installation category CAT III 300 V
Consumption 4,7 VA
Frequency 50 … 60 Hz
Nominal voltage 230 V ~ (±10 %)
 
MECHANICAL CHARACTERISTICS
Size (mm) width x height x depth 144 x 144 x 54.85 (mm)
Envelope Plastic V0 self-extinguishing
Cable gauge at power supply terminals ≥1,5 mm2
Cable gauge at input and output terminals ≥1,5 mm2
Cable gauge at current terminals ≥1,5 mm2
Fastening Panel
Weight (kg) 0,555
 
ENVIRONMENTAL CHARACTERISTICS
Protection class IP 30 / Front Panel: IP 40 IK 08
Relative humidity (without condensation) 5 … 95 %
Storage temperature -20 … +70 ºC
Operating temperature -20 … +60 ºC
 
CURRENT MEASUREMENT CIRCUIT
Nominal current (In) … / 5 A
Phase current measuring range 0.05 … 5A
Permanent overload + 20%
Connection Connect preferably to phase L1
 
COMMUNICATIONS
Band 2,4 GHz.
Standards IEEE 802.11 b / g , IEEE 802.11 n (hasta 150 Mbps)
Maximum output power IEEE 802.11 b: 20 dBm / IEEE 802.11 n: 14 dBm
Connection mechanism Autodetectable Wi-Fi
Technology Wi-Fi
 
STANDARDS
Electrical safety, Maximum height (m) 2000
Electrical safety, Contamination level/class Pollution resistance 2
Standards IEC 61010, IEC 61000-2-30, IEC 61000-6-4, IEC 61000-6-2
 
ELECTRICAL SAFETY
Insulation Double-insulated electric shock protection class II (IEC 61010-1)
 
USER INTERFACE
Resolution of the display 3 digits
Keyboard 3 keys
 
DIGITAL RELAY OUTPUTS
Quantity 6 + 1 (Alarm)
Maximum current 1 A~
Maximum open contact voltage 250 V~
Electrical life (at maximum load) 1×105 cycles
Mechanical life 1×107 cycles
Maximum switching capacity 250 W
 
MEASUREMENT ACCURACY
Phase angle φ 2 % ± 1 digit
Phase current measurement 1%
Phase voltage measurement 1%